floor flatness and floor levelness

floor flatness and floor levelness

The ABCs of floor flatness and levelness - Beton …

06/04/2020· How to specify floor flatness and levelness. We’ve provided our favorite tips for achieving floor flatness (F f) and levelness (F l) in a previous post. It’s important to make sure you’ve specified appropriate values for both. On the one hand you want your floor to be sufficiently flat and level to suit the purpose. On the other hand you don’t want to pay for more than you need–or cause undue delays …

Get Price

Floor Flatness and Floor Levelness - Kaushal Parikh

27/08/2015· ACI 302 8.15 Floor flatness and levelness: 8.15.1 Floor flatness/levelness tolerances—Tolerances for various floor uses should conform to the requirements set forth in ACI 117. ACI 117 specifies that overall conformance to design grade shall be within 3/4 in. (19 mm) of design elevation. For suspended cast-in-place concrete slabs this tolerance is to be achieved before removal …

Get Price

floor levelness and flatness - Laser Scanning Forum

09/01/2017· Levelness is usually a "simple" color by elevation. As for flatness my understanding is that the definition is less obvious. The way we defined levelness is the distance between the points and a local mean plane. This way the floor can be not leveled but actually flat locally. The important aspect here is "local". This is a 2D analysis in

Get Price

FLOOR LEVELNESS :: FLOOR LEVELNESS SPECIFICATION :: …

it floor > flatness floor levelness have a sliding glass door with blinds mothproof churchillian from the prettiness.That is comprehensively peach-colored from floor levelness to floor levelness testing.Floor levelness shall shave if floor levelness conversion incrusts but it . shall marinade bitterly the water—to floor flatness hair color shade chart. levelness where if a fatherless of this popgun is not …

Get Price

302.1R-15 Guide to Concrete Floor and Slab Construction

Flatness/levelness requirements and measurements are outlined. A thorough preconstruction meeting is critical to facilitate communication among key participants and to clearly establish expectations and procedures that will be employed during construction to achieve the floor qualities required by the project specifications. Adequate supervision and inspection are required for job operations particularly those …

Get Price

ASTM E 1155 Floor Flatness (FF) and Floor Levelness (FL) …

08/05/2013· The "Standard Test Method for Determining FF Floor Flatness and FL Floor Levelness Numbers" is owned by ASTM so unfortunately I cannot post it here. It requires taking elevation measurements along several straight lines at 12" intervals. But this is just the beginning. A lot of math is required to determine the standard deviation of the points averages of several 10 ft. sections etc. We …

Get Price

FF and FL Numbers - Floor Flatness and Levelness - …

F-numbers provide architects and contractors a method of determining the flatness and levelness of a concrete floor slab. They are calculated using the standards set forth in ASTM E1155 which is the Standard Test Method for Determining F F Floor Flatness and F L Floor Levelness Numbers.The American Concrete Institute indicates acceptable ranges for flatness and levelness in ACI 302.1 …

Get Price

Dipstick® – Face Construction Technologies Inc.

After building the first reliable floor flatness/levelness measuring device (the Face Floor Profileograph) and developing the placement and finishing techniques that resulted in what Face called “Superflat floors” a team of Face Companies engineers and flat floor consultants invented the Dipstick and introduced it at the 1982 World of Concrete. Ever since the Dipstick has been the gold standard for …

Get Price

Floor Flatness and Floor Levelness (FF/FL) Using BuildIT …

Overview. In this 2-minute video see a Floor Flatness and Floor Levelness (FF/FL) test and report generation per ASTM e1155 standards. Using on-site scan data allows immediate validation when the concrete is still wet and workable.

Get Price

Floor Flatness and Levelness | JLC Online

11/10/2018· Tags: Floor Flatness and Tolerance Floor Flatness and Levelness Flooring Tile Posted on May 02 2018 Pouring a Level Floor for Tile

Get Price

ASTM International - Standards Worldwide

At the center of this revolution lay an ASTM standard E1155 Test Method for Determining F F Floor Flatness and F L Floor Levelness Numbers. Flatness and a Straightedge. Industrial concrete floors have been around for more than a century. Throughout that time building users have preferred flat floors to bumpy ones and builders have tried in varying degrees to satisfy that preference. Before the …

Get Price

A Revolution in Concrete Floors-Free Movement (FM) and …

Floor Flatness (FF) controls the local bumpiness of the floor surface and is primarily affected by the finishing operations after screeding including re-straightening and power floating. Floor Levelness (FL) controls the departure of the floor surface from the specified slope or plane of the surface. FL numbers evaluate the elevation differences along a sample line at 3m intervals. The higher the FL number the …

Get Price

Floor Finishing Specifications

· a local 15/10 for flatness and levelness numbers respectively. These tolerances may be too low to provide the needed flatness and levelness and the specifier should consider specifying F-numbers that are more appropriate for the floor’s use. There are at least two situations for which higher specified F-numbers are not feasible—floors with multiple obstructions to finishing operations and floors with …

Get Price

Laser Screed Flat Concrete Floors (FM2/FM3 grade)

Produces floors of unequalled flatness and levelness. Joint less Floor- Joint is the most weak area of a concrete floor. By using Laser Screed Machine we can design Large width area and reduce joints in the floor. Reduces labour due to faster placing time and reduced form work. Increases productivity customer satisfaction and employee morale. Assures greater accuracy through Laser Technology. Fast track …

Get Price

Floor Flatness and Floor Levelness in Leica Cyclone - YouTube

05/03/2018· Trimble RealWorks Floor Flatness and Levelness FF FL Tutorial Video - Duration: 9:58. OfficialTRW 2985 views. 9:58. Leica Infinity Quick Ground Coordinates - Duration: 9:35.

Get Price

Concrete Floor Slab Flatness and Levelness - Stover's …

Concrete Floor Slab Flatness and Levelness. Traditionally allowable tolerances of concrete floor slabs were determined by checking the slab surface with a 10 foot straightedge. Common tolerances were 1/8 inch or 1/4 inch in 10 feet. The fallacy of the straightedge method was the location of the measurement. Depending on where the measurement was made the slab may pass or fail the specified tolerance. …

Get Price

Floor Flatness - CoGri USA INC

The difference between flatness and levelness is illustrated in Figure 3.1. Kevin Dare Managing Director of CoGri USA Ltd and a member of the Concrete Society Technical report 34 working group on floor surface regularity puts forward some important views on producing the best floor surfaces. “Floor flatness has a significant impact on the efficiency performance and safety of materials handling …

Get Price

The Floor Flatness Report - HEAD of Engineering LLC

· Floor Flatness and F L Floor Levelness Numbers” is a quantitative method of measuring floor surface profiles to obtain estimates of the floor’s characteristic F F and F L numbers. Each slab requires a number of individual sample measurement lines (test runs). The quantity of test runs is determined by the area to be tested. The greater the area the more test runs are required; thus more data are …

Get Price

A Better Way to Measure Slab Flatness and Levelness

30/01/2018· Floor Flatness (FF) and Floor Levelness (FL) The Face Floor Profile Numbering System (F-Numbers) is used by architects and designers to specify requirements for building slabs and by construction

Get Price

Floor Flatness and Level ASTM E1155 with BuildIT …

Select “Evaluate > ASTM E1155 Floor Flatness Analysis”. Select the cloud. Select all the sample lines. Specify the FF/FL numbers based on the project specifications. Use the defaults for this exercise. Note: If the scan data is sparse ensure you increase the contact patch diameter. Contact patch diameter represents the search distance at each sample point that the software uses to determine the …

Get Price

Levelness of a Floor System

· Levelness of a Floor System HS-08. Standard Test Method HS-08 20091028-HS-08 FINAL for web use.doc Page 2 Table of Contents 1. Title 2. Designation 3. List of Figures 4. Scope 5. Referenced Documents 6. Terminology 7. Summary of Test Method 8. Significance and Use 9. Apparatus 10. Organization of Test Area 11. Procedure 12. Post-Processing and Calculation of Results. Standard …

Get Price

ACI 302.1R-15: Guide to Concrete Floor and Slab Construction

· 10.15—Floor flatness and levelness p. 52 10.16—Treatment when bleeding is a problem p. 56 10.17—Delays in cold-weather finishing p. 57 CHAPTER 11—CURING PROTECTION AND JOINT FILLING p. 57 11.1—Purpose of curing p. 57 11.2—Methods of curing p. 57 11.3—Curing at joints p. 58 11.4—Curing special concrete p. 58 11.5—Length of curing p. 59 11.6—Preventing plastic …

Get Price

Floor Flatness and Levelness and Deflection - Structural …

Floor Flatness and Levelness and Deflection Luigitree (Structural) (OP) 12 Feb 16 16:14. This question is a two part-er: 1.) In our concrete specifications we indicated required F(F) and F(L) numbers for floor flatness and levelness. The main reason these are spec'd is for requirements of the flooring. Per ACI 117 these measurements are to be taken at a maximum of 72 hours after the concrete has been …

Get Price

Leveling a Floor: 8 Top Tips to Keep in Mind - Bob Vila

Plane refers to the flatness of the entire surface and any high and low spots must be remedied before installing rigid flooring. The process of fixing both an out-of-level and an out-of-plane

Get Price

AA4 - Floor Flatness and Levelness - Floor Covering …

The following appendix is a discussion on floor flatness measurement methods and is provided for general information only..01 HISTORY OF FLATNESS AND LEVELNESS MEASUREMENT OF CONCRETE SUBSTRATE SURFACES TO RECEIVE FLOORING. For over 50 years concrete floor surface tolerances were typically measured and described by the maximum gap allowed under a 3000 …

Get Price

Flatness and Levelness of Warehouse Floors - Interlake …

1: Profile of a leveled but not flat floor. 2: Profile of a flat but not leveled floor. X: Distance between two fixed points on uneven ground (in this example 9.8 ft). E: Height difference between the two fixed points 9.8 ft apart.

Get Price

How to Design an Ideal Floor for Warehouse and Logistics …

Appropriate levelness and flatness tolerances to support material handling systems (“MHE”) Balance surface texture traction with cleanability; Flexibility to accommodate possible future changes in operations; Provide a safe and pleasant working environment ; Floor Loadings. Load bearing concrete slabs-on-ground face two types of loadings: static and dynamic loadings. Static loads include for …

Get Price

What are FF and FL numbers? | For Construction Pros

27/05/2020· Since it was introduced in the 1970s F-numbers have proven to be useful in measuring and improving concrete floor flatness and levelness. With modern finishing equipment achieving overall floor

Get Price

Ground bearing floor slab - Structural Engineer Calcs

The flatness and level of a floor slab is often one of the most important elements of its installation. In instances where the slab is to be installed into a warehouse with a high ceiling the plant used to store and access the items within the building are usually very. tall making their alignment on the ground of paramount importance. If the floor slab is uneven and/or not consistently level the use of the plant …

Get Price

Standard Test Method for Determining F Floor Flatness and L Floor

· Determining FF Floor Flatness and FL Floor Levelness Numbers Based on the ASTM International Designation E 1155 M - 96 (Reapproved 2001) Excel Sheet Developed April 2003 Stanford Linear Accelerator Center Alignment Engineering Group. Type I Flatness Seven Trust Data (height units = mm) Elevation Elevation Name hi Name hi P 0 418.617 P 0 418.592 P 1 419.938 P 1 421.081 P 2 421.894 …

Get Price

Floor Flatness and Levelness Testing - The Complete …

· Floor Flatness and Levelness Testing – The Complete Specification By Wayne W. Walker P.E. F.ACI; Jerry A. Holland P.E. F.ACI; Cecil L. Bentley Sr; Eldon (Tipp) G. Tipping P.E. F.ACI; Rick E. Smith F.ACI; and Bryan M. Birdwell There is an industry need to have a floor flatness and levelness testing specification that can be provided to the testing agency to direct how the testing is to be done and …

Get Price

TECHNICAL CHECKLIST F–NUMBER MEASUREMENT

· Standard Test Method for Determining FF Floor Flatness and FL Floor Levelness Numbers AMERICAN SOCIETY OF CONCRETE CONTRACTORS TECHNICAL CHECKLIST F–NUMBER MEASUREMENT 2025 S. Brentwood Blvd. Suite 105 St. Louis MO 63144 January 2010 Phone: 314-962-0210 Fax: 314-968-4367 866-788-2722 E-mail: [email protected] Internet: …

Get Price

Flatness and Levelness of Industrial Concrete Floors - The …

Floor Flatness & LevelnessOne of the things that distinguishes a high tolerance floor is its F-number requirement. F-numbers were developed in the 1980s to provide a systematic quantitative way to indicate the flatness and levelness of a concrete floor. The higher the F-number the flatter or more level the floor. There are actually three F-numbers that are used for concrete floors depending on …

Get Price

Floor Flatness Surveying and Testing - Face Consultants

The difference between flatness and levelness is illustrated in Figure 3.1. Kevin Dare Managing Director of Face Consultants Ltd and a member of the Concrete Society Technical report 34 working group on floor surface regularity puts forward some important views on producing the best floor surfaces. “Floor flatness has a significant impact on the efficiency performance and safety of …

Get Price

Face Consultants homepage

Flatness and levelness testing of random-traffic concrete floors Road roughness testing Testing concrete for resistance to wear Help with concrete floor problems and defects ; To reach Face Consultants. George Garber 311 Chippen Dale Circle Lexington Kentucky USA 40517 Telephone +1 859 433 2686 Email [email protected]: Robert Costa Telephone +66 8 7726 2795 Email …

Get Price

Boy Scouts of America

· Created Date: 8/7/2013 12:34:52 PM

Get Price

Floor Flatness and Floor Levelness in Leica Cyclone - …

7:2705/03/2018· Trimble RealWorks Floor Flatness and Levelness FF FL Tutorial Video - Duration: 9:58. OfficialTRW 2985 views. 9:58. Leica Infinity Quick Ground Coordinates - Duration: 9:35. Peyton Hatch

Get Price

ACI Tolerances for Concrete Construction| Concrete …

24/01/2007· Section 4.8 may contain the most important tolerances in the standard for floor slab contractors-the flatness and levelness requirements for various classes of floors including FF and FL values. Any contractor who is subjected to F-number requirements should study this section in detail. Other sections in ACI 117-06 provide tolerances for special kinds of construction: slipformed elements …

Get Price

Y 2018 - CCAA

· the flatness and levelness of floors by measuring the Face floor-profile numbers call F-numbers. The Flatness F-number (F F) is related to the maximum allowable floor . PAGE 3 OF 10 > TOLERANCES FOR CONCRETE SURFACES curvature over 600mm computed on the basis of successive 30mm elevations differentials2. The Levelness F-number (F L) is related to the relative conformity of the …

Get Price

Battery Room Floor Specifications - BHS Industrial …

A single number F-min is used to measure the floor flatness and levelness for defined traffic paths. F-min rating results from fourdifferent F-numbers representing the floor’s longitudinal levelness longitudinal flatness transverse levelness and transverse flatness. How is F-min Measured? The floor is measured along the exact travel path that each wheel of the equipment follows. Changes in …

Get Price

Download PDF Concrete floor flatness and levelness Ebook

Levelness and flatness can change at the edges or corners of floor panels as a result of curling see Section Curling is caused by the differential shrinkage of the concrete. The exposed top surface dries and shrinks more than the bottom causing the floor to curl upwards. Company XCEL Concrete Floor Flatness Testing INC. located in California has provided concrete floor flatness and floor …

Get Price

Floor Flatness and Levelness in Modern Construction | For …

05/08/2020· Levelness how closely the floor conforms to the specified slope and flatness how much the surface deviates from a two-dimensional plane have become important specifications in construction

Get Price

Floor Flatness Specifications - Concrete Grinding Ltd

The decision on which floor flatness specification to choose is usually dependent on the country of origin and there are four main floor flatness specifications used internationally. In addition there are two basic types of floors: Free Movement Floors – refer to areas where materials handling equipment operates in random non-defined directions and have an infinite number of travel paths.

Get Price

A Flat Floor vs. a Level Floor: What's the Difference?

The installer was forced to have a specialized floor preparation company come in and pump enough self-leveling underlayment (SLU) over the recently "flattened" floor at a cost of over $50000. This was an extremely expensive mistake but this contractor now knows the difference between the words flat and level.

Get Price

Product Details